ISCC EU · UCO GHG evidence
ISCC EU certification for UCO processors: which GHG emission factors can you use?
Prepare emission-factor evidence for an ISCC EU UCO calculation. Check prescribed sources, justify alternatives and trace units before relying on a GHG result.

For an ISCC EU GHG calculation, a UCO processor should first check whether the applicable emission factor is provided in Commission Implementing Regulation (EU) 2022/996. ISCC’s official guidance says appropriate factors from that regulation must be used. An old workbook, a familiar national inventory factor or a lower number is not sufficient justification for choosing something else.
Mason Ali is BM Certification’s ISCC representative for Australia and New Zealand. Get-ISO handles enquiries and coordinates the certification pathway. The ISCC directory lists BM Certification SIA, identifier LT227, for ISCC EU and ISCC CORSIA among its cooperating schemes. BM Certification makes certification decisions and issues certificates where it is the appointed certification body.
Agree the GHG method before selecting a factor
ISCC EU 205 v4.2 describes different options for providing GHG information, including applicable default values and actual calculations. An emission factor used to convert activity data into emissions is not the same thing as a default value for a fuel pathway. Confirm which method applies to your activity and claim before populating the workbook.
This checklist is for a UCO treatment or processing operator preparing evidence for an actual calculation under ISCC EU. It does not require every UCO collector or trader to prepare a complete fuel life-cycle calculation. Identify your actual role, process boundary and downstream data request with the appointed body.
What if no suitable factor is available?
ISCC’s emission-factor FAQ says alternative sources may be considered where the regulation has no applicable factor. Such values need justification, a clear flag in the calculation and verification of applicability by the certification body. It also says that continued use of factors from older versions of ISCC EU 205 is not allowed. Retain the source and retrieval date; do not treat a previous audit as permanent approval for a factor.
Prepare a factor evidence file the reviewer can follow
The following is Get-ISO’s suggested review workflow, not an additional scheme form or certification guarantee.
- Describe the activity. The process owner lists the actual equipment, energy input and site location. Distinguish grid electricity, purchased heat and fuel use instead of applying one generic “energy” factor to all three.
- Keep quantity and factor evidence separate. Link the activity quantity to its meter, invoice or other supporting record. Link the factor to the applicable source entry. One electricity bill cannot establish both how much energy was used and which GHG factor is permitted.
- Record the selection basis. The calculation owner records the source title, version or relevant date, exact table or entry, units, geographical coverage and why it fits the activity. Mark unresolved applicability rather than choosing the lowest available value.
- Check units and boundaries. Have a competent reviewer follow the conversion through the workbook. Check whether quantities and factors use compatible energy units and whether the emissions boundary matches the methodology. Identify any required conversions explicitly; do not rely on an unexplained multiplier.
- Control alternatives and changes. Where an alternative is proposed, retain the search for an applicable prescribed factor, justification and the body’s response. Keep a change log showing which cells and reported outputs were affected by an approved update.
Worked example — a heater workbook has an unexplained factor
A UCO processor prepares an actual-value evidence pack for an electrically heated preparation line. Its workbook contains a factor copied from an earlier job. The cell has no source reference or units, and the reviewer cannot establish whether it represents the site’s electricity supply. This example is illustrative, not a client case or a worked ISCC calculation.
The site’s calculation owner preserves the original workbook and marks the result as awaiting review. The process owner supplies the relevant meter and operating-period records. The reviewer checks the applicable regulatory source, documents the factor selection and traces any unit conversions. If no applicable factor can be identified, the question and proposed alternative go to the certification body before the result is relied on.
Retain the original and revised versions, the reason for the change, supporting source entry and review decision. Recheck the affected outputs. Replacing the cell does not by itself demonstrate that shared energy allocation, material quantities or the rest of the calculation are correct. No emission value, saving or certification outcome is established by this example.
Separate EU fuel claims from CORSIA
UCO may enter supply chains for FAME biodiesel, HVO renewable diesel or HEFA sustainable aviation fuel. State the intended market and scheme when requesting certification. For an EU claim, use the applicable ISCC EU GHG method. For a CORSIA claim, assess the separate ISCC CORSIA criteria; a factor accepted for one scheme is not automatically suitable for the other.
Official references and certification enquiries
Sources reviewed on 24 November 2026: ISCC’s current public emission-factor guidance; the EUR-Lex record for Implementing Regulation (EU) 2022/996; and ISCC EU 205 v4.2, valid from 21 May 2025. Check the applicable regulation version, ISCC document library and system updates when finalising your evidence.
For the separate process-scope decision, read the UCO filtration and heating scope guide. Contact Get-ISO through the ISCC certification coordination service to discuss initial certification, recertification or a change of certification body. Explain which calculation or data request needs review; agree a secure method before sharing detailed commercial files.
General guidance. Use the applicable standard, scheme documents and agreed engagement criteria. Examples are illustrative and do not establish a certification outcome.