Use PDCA to assess a compressed-air leak report. Define the improvement opportunity, control production and safety risks, and check comparable operating data.

When an operator reports a compressed-air leak, record the defect and assess whether a planned repair offers a measurable improvement. Keep the expected benefit separate from the risks of changing the system. Authorise the work through the site’s maintenance controls, then compare equivalent operating conditions before deciding that the change worked.

Illustrative Get-ISO operator practice

You hear a persistent hiss near the air supply for a packaging machine. A colleague suggests turning down the supply pressure to reduce compressor running time. The machine uses pneumatic actuators and has an approved operating range. What would you report, who should decide the action and what would you check after the work?

Plan — describe the opportunity and the risks

The operator records the equipment ID, location and operating conditions without touching the connection. The maintenance supervisor assesses the defect and arranges the response. The process owner records the improvement opportunity as reducing avoidable air demand while maintaining the required machine performance. Quality identifies the product and cycle checks to be met. Workers and the safety lead identify hazards associated with the work, including stored pneumatic energy and unexpected movement.

Keep the defect report, proposed work, acceptance criteria and measurement plan together. The authorised technical owner decides the appropriate repair and confirms the approved settings. Ask what data can support a comparison, such as compressor energy or running hours, machine hours and accepted production volume. Identify unrelated users of the same compressor so their demand can be considered.

Do — complete the authorised work and record what changed

Competent maintenance personnel follow the site’s approved isolation and maintenance arrangements. Retain the work order and record the component or connection repaired, checks completed and authorised restart. The supervisor briefs affected operators on any approved operating changes and records the settings used for the comparison. Quality holds the trial output until the agreed checks pass.

Check — compare like with like

Suppose the baseline records 32 compressor running hours over a period producing 8,000 accepted units. A later period records 24 hours but produces only 4,000 units. The absolute hours fell, but the ratio rose from 4 to 6 running hours per thousand accepted units. These figures are illustrative. Shared users, operating schedules and the limits of running hours as a proxy for energy must also be investigated before attributing a result to the repair.

  • Quality: The process owner checks cycle performance, stoppages and accepted output against the approved criteria.
  • Environment: The environmental lead compares measured energy where available, production and operating conditions, explaining data gaps and shared demand.
  • Safety: The supervisor verifies the handback checks and asks workers whether the repaired setup creates any new access, noise or operating concern.

Act — decide whether the evidence supports wider action

If the product or safety checks fail, follow the site’s hold and escalation process. If the comparison cannot establish a benefit, retain the repair record and improve the measurement plan before claiming a saving. Check performance on a later comparable shift, assign any further action and retain the evidence behind the decision. Use recurring leak reports to plan maintenance priorities with the operators who use the equipment.

Published editions and practical references

ISO’s ISO 9001:2026 overview identifies clearer treatment of risks and opportunities. This exercise applies that change by recording a proposed benefit and evaluating the conditions that could prevent it. Use ISO 14001:2026 for applicable environmental performance considerations and ISO 45001:2018, including its 2024 climate action amendment, as applicable to your safety system.

See WorkSafe Victoria’s plant isolation guidance and ASQ’s PDCA guide for the supporting methods. Use the related water-saving trial exercise to practise another performance comparison, or discuss evidence review through the ISO 9001 gap assessment service.

General guidance. Use the applicable standard, scheme documents and agreed engagement criteria. Examples are illustrative and do not establish a certification outcome.

All resources · Related service

Call Mason